AWG | 4 |
---|---|
Area (mm) | 4.8 |
Diameter (mm) | 7.8 |
SFX/8C-TY3-SCR-LSF-WHT-200
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | Y |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.60 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 6.8 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501657 |
Flame Propagation Standard | Eca |
AI-PET Shield | >=115% |
Drain wire conductor | Tinned Copper Clad Aluminium |
SFX/8C-TY3-SCR-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | Y |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.60 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 2.6 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501640 |
Flame Propagation Standard | Eca |
AI-PET Shield | >=115% |
Drain wire conductor | Tinned Copper Clad Aluminium |
SFX/8C-TY3-SCR-LSF-WHT-1
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.60 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 0.026 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501633 |
AI-PET Shield | >=115% |
Drain wire conductor | Tinned Copper Clad Aluminium |
SFX/8C-TY3-SCR-PE-BLK-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | Y |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.60 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 2.2 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501664 |
Flame Propagation Standard | Fca |
AI-PET Shield | >=115% |
Drain wire conductor | Tinned Copper Clad Aluminium |
SFX/8C-TY3-PVC-WHT-200
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 6.3 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501626 |
SFX/8C-TY3-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 2.3 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501619 |
Flame Propagation Standard | Eca |
SFX/8C-TY3-PVC-BLK-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PVC |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 2.2 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501602 |
Flame Propagation Standard | Eca |
SFX/8C-TY3-PE-BLK-500
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 10 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501596 |
Flame Propagation Standard | Fca |
SFX/8C-TY3-PE-BLK-200
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 3.7 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501589 |
Flame Propagation Standard | Fca |
SFX/8C-TY3-PE-BLK-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 1.9 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501572 |
Flame Propagation Standard | Fca |
SFX/8C-TY3-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.019 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501565 |
Flame Propagation Standard | Fca |
SFX/8C-TY3-LSZH-WHT-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSZH |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | LSZH |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 3.1 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
SFX/8C-TY3-LSF-WHT-500
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 15 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501558 |
Flame Propagation Standard | Eca |
SFX/8C-TY3-LSF-WHT-200
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 4.3 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501541 |
Flame Propagation Standard | Eca |
SFX/8C-TY3-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 2.3 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501534 |
Flame Propagation Standard | Eca |
SFX/8C-TY3-LSF-WHT-1
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 0.0023 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501527 |
Flame Propagation Standard | Eca |
SFX/8C-TY3-LSF-BRN-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | Brown RAL 8011 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | LSF |
Overall Colour | Brown |
Rated Voltage (V) | 30V |
Weight | 2.2 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501510 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-SCR-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | Y |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.40 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 2.1 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501367 |
Flame Propagation Standard | Eca |
AI-PET Shield | >=115% |
Drain wire conductor | Tinned Copper Clad Aluminium |
SFX/6C-TY3-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 2 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501350 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-PVC-BLK-100
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | PVC |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 1.8 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501343 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-LSF-WHT-500
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 10 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501336 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-LSF-WHT-200
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 3.8 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501329 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 1.9 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501312 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-LSF-BRN-100
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | Brown RAL 8011 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | LSF |
Overall Colour | Brown |
Rated Voltage (V) | 30V |
Weight | 1.9 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501299 |
Flame Propagation Standard | Eca |
SFX/6C-TY3-DB-BLK-1000
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 30 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501282 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 4.00 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/6C-TY3-DB-BLK-1
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.03 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501275 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 4.00 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/4C-TY3-SCR-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N, Y |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 3.90 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 1.7 |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500810 |
Flame Propagation Standard | Eca |
AI-PET Shield | >=115% |
SFX/4C-TY3-PVC-BLK-100
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 3.50 ±0.200 |
Overall Sheath | PVC |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 1.5 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500803 |
Flame Propagation Standard | Eca |
SFX/4C-TY3-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 3.50 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 1.5 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500797 |
Flame Propagation Standard | Eca |
SFX/12C-TY3-SCR-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N, Y |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 6.00 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 4.2 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500629 |
Flame Propagation Standard | Eca |
AI-PET Shield | >=115% |
SFX/12C-TY3-PE-BLK-200
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 7.4 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500612 |
Flame Propagation Standard | Fca |
SFX/12C-TY3-PE-BLK-100
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 3.1 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500605 |
Flame Propagation Standard | Fca |
SFX/12C-TY3-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.037 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500599 |
Flame Propagation Standard | Fca |
SFX/12C-TY3-LSF-WHT-500
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 18 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500582 |
Flame Propagation Standard | Eca |
SFX/12C-TY3-LSF-WHT-200
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 7.4 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500575 |
Flame Propagation Standard | Eca |
SFX/12C-TY3-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 3.6 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500568 |
Flame Propagation Standard | Eca |
SFX/12C-TY3-LSF-WHT-1
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Yellow 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | LSF |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 0.036 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500551 |
SFX/12C-TY3-DB-BLK-1000
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Yellow 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 43 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500544 |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 5.40 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/12C-TY3-DB-BLK-1
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Yellow 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.043 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500537 |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 5.40 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/4C-TY3-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | Tinned Copper Clad Aluminium |
Conductor Diameter (mm) | 0.20 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Yellow 210D |
Jacket | PVC |
Jacket Colour | White RAL 9005 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 3.50 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 1.5 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500803 |
Flame Propagation Standard | Eca |