Alarm Cable Type 2 8 Cores Screened Direct Burial HDPE - Black 1000m
SFX/8C-TY2-SCR-DB-BLK-1000
To become or find a stockist contact us
Available in a range of sheathing types to suit individual needs, Type 2 Alarm Cable is used for hard-wired alarm, security systems and other low voltage circuits. It connects elements of the system together, allowing for normal operation of all components.
A number of our Type 2 Premium Alarm Cables are Direct Burial Alarm cables, designed to be installed directly into the ground without the need for ducting. Direct Burial Cable withstands any moisture and will not suffer any damage if exposed to damp environments. The strength and quality of DB sheath allows for maximum protection for the internal construction of the cable.
Available in tinned copper or TCCA conductor with a double PE sheath, these cables are ideal for external use within intruder alarm and security systems and other low voltage circuits.
Designed for use within intruder alarm and security systems and other low voltage circuits.
Results | |
AWG | 4 |
---|---|
Area (mm) | 4.8 |
Diameter (mm) | 7.8 |
SFX/8C-TY2-SCR-DB-BLK-1000
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | Y |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 4.60 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 35 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501503 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 4.60 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
Drain wire conductor | Tinned Copper |
AI-PET Shield | >=115% |
SFX/8C-TY2-SCR-DB-BLK-1
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | Y |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 4.60 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.035 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501497 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 4.60 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
Drain wire conductor | Tinned Copper |
AI-PET Shield | >=115% |
SFX/8C-TY2-PVC-WHT-200
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 6.3 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501480 |
Flame Propagation Standard | Eca |
SFX/8C-TY2-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 3.2 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501473 |
Flame Propagation Standard | Eca |
SFX/8C-TY2-PVC-WHT-1
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Red 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 0.032 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501466 |
SFX/8C-TY2-DB-BLK-1000
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 35 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501459 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 4.20 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/8C-TY2-DB-BLK-1
To become or find a stockist contact us
Cable Construction | 8 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 4.20 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.035 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501442 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 4.20 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/6C-TY2-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 6 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 4.00 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 2.6 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631501268 |
Flame Propagation Standard | Eca |
SFX/4C-TY2-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 3.50 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 1.9 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500780 |
Flame Propagation Standard | Eca |
SFX/12C-TY2-SCR-DB-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N, Y |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 6.00 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 43 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500520 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 6.00 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
AI-PET Shield | >=115% |
SFX/12C-TY2-SCR-DB-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N, Y |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 6.00 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.043 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500513 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 6.00 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
AI-PET Shield | >=115% |
SFX/12C-TY2-PVC-WHT-100
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket | PVC |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | PVC |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 4.8 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500506 |
Flame Propagation Standard | Eca |
SFX/12C-TY2-LSF-WHT-200
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Red 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 9.7 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
SFX/12C-TY2-LSF-WHT-100
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | PVC |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Nylon Rip-Cord | Red 210D |
Jacket | LSF |
Jacket Colour | White RAL 9003 |
Jacket Thickness (mm) | 0.5 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | White |
Rated Voltage (V) | 30V |
Weight | 4.9 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Eca |
Application | For the interconnection of intruder alarm installations. |
SFX/12C-TY2-DB-BLK-1000
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 43 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500490 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 5.40 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 0.6 |
SFX/12C-TY2-DB-BLK-1
To become or find a stockist contact us
Cable Construction | 12 Cores |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 7 |
Stranded Diameter (mm) | 0.22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.21 |
Insulation Colour | Red,Black,Blue,Yellow,Green,White,Orange,Brown,Turquoise,Pink,Violet,Grey |
Insulation Thickness 2 (mm) | 1.00 ±0.100 |
Drain Wire | N |
Nylon Rip-Cord | Red 210D |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 5.40 ±0.200 |
Overall Sheath | HDPE |
Overall Colour | Black |
Rated Voltage (V) | 30V |
Weight | 0.043 |
Compliance and Standards | BS4737-3.30:2015,RoHS2 2011/65/EU |
CPR | Fca |
Application | For the interconnection of intruder alarm installations. |
EAN | 5056631500483 |
Flame Propagation Standard | Fca |
Inner Jacket | HDPE |
Inner Jacket Diameter (mm) | 5.40 ±0.100 |
Inner Jacket Thickness (mm) | 0.6 |
Inner Jacket Colour | Black RAL 9005 |
Outer Jacket | HDPE |
Outer Jacket Colour | Black RAL 9005 |