SY Control Flex Cables 7 Core 1.5mm Numbered Cores PVC - Clear 500m
SFX/SY-7C-1.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
SY cable, also known as armoured flex, shielded flex or armoured control cable are commonly used in industrial applications where flexibility, strength or harsh environments affect installation. Often under mechanical stresses, these control cables are used to connect control and mechanical applications where flexibility and movement is required. Our SY control flex (often referred to as multi core flex), is constructed with copper conductors, a galvanised steel wire braid for mechanical protection, and transparent PVC sheath.
SY cables, although predominantly used for internal applications, can be used externally if installed within a conduit to protect it from ultraviolet light.
Designed for use in control, signalling, protection, and measurement systems predominantly within industrial computer programming applications.
Results | |
AWG | 4 |
---|---|
Area (mm) | 4.8 |
Diameter (mm) | 7.8 |
SFX/SY-7C-1.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 7 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.40mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 10.50 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 20A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 101.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512455 |
Flame Propagation Standard | Eca |
SFX/SY-7C-1.5-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 7 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.40mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 10.50 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 20A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.203 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512448 |
Flame Propagation Standard | Eca |
SFX/SY-5C-6.0-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 5 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.60mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 15.50 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 44A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 239.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512431 |
Flame Propagation Standard | Eca |
SFX/SY-5C-6.0-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 5 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.60mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 15.50 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 44A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.479 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512424 |
Flame Propagation Standard | Eca |
SFX/SY-5C-4.0-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 5 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 13.20 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 34A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 169 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512417 |
Flame Propagation Standard | Eca |
SFX/SY-5C-4.0-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 5 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 13.20 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 34A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.338 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512400 |
Flame Propagation Standard | Eca |
SFX/SY-5C-2.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 5 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 11.80 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 25A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 125 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512394 |
Flame Propagation Standard | Eca |
SFX/SY-5C-2.5-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 5 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 11.80 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 25A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.25 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512387 |
Flame Propagation Standard | Eca |
SFX/SY-4C-2.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 10.60 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 25A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 101 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512370 |
Flame Propagation Standard | Eca |
SFX/SY-4C-2.5-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 10.60 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 25A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.202 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512363 |
Flame Propagation Standard | Eca |
SFX/SY-4C-1.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.40mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 9.00 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 20A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 68.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512356 |
Flame Propagation Standard | Eca |
SFX/SY-4C-1.5-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 4 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.40mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 9.00 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 20A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.137 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512349 |
Flame Propagation Standard | Eca |
SFX/SY-3C-6.0-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.60mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 13.10 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 44A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 163.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512332 |
Flame Propagation Standard | Eca |
SFX/SY-3C-6.0-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.60mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 13.10 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 44A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.327 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512325 |
Flame Propagation Standard | Eca |
SFX/SY-3C-4.0-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 34A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 114.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512318 |
Flame Propagation Standard | Eca |
SFX/SY-3C-4.0-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 34A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.229 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512301 |
Flame Propagation Standard | Eca |
SFX/SY-3C-2.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 9.80 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 25A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 84.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512295 |
Flame Propagation Standard | Eca |
SFX/SY-3C-2.5-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.50mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 9.80 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 25A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.169 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512288 |
Flame Propagation Standard | Eca |
SFX/SY-3C-1.5-PVC-CLR-NBR-U-500
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.40mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 8.40 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 20A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 58.5 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512271 |
Flame Propagation Standard | Eca |
SFX/SY-3C-1.5-PVC-CLR-NBR-U-1
To become or find a stockist contact us
Cable Construction | 3 Cores |
---|---|
Conductor | IEC 60228/ DIN EN 60228/ EN 60228 Class 5 Stranded Electrolytic Plain Copper |
Insulation | EN 50363-3 PVC Compound |
Insulation Thickness (mm) | 0.40mm |
Insulation Colour | Black numbered cores plus Earth |
Drain Wire | N |
Inner Jacket | EN 50363-4-1 PVC Compound |
Armour | Galvanized Steel Wire Braid ( Coverage) |
Jacket Colour | Clear |
Outer Jacket | EN 50363-4-1 PVC Compound |
Outer Jacket Colour | Clear |
Overall Diameter (mm) | 8.40 |
Overall Sheath | PVC |
Overall Colour | Clear |
Rated Voltage (V) | 300/500V |
Current Capacity in air (A) | 20A |
Min Bend Radius (mm) | 10 x Ø |
Weight | 0.117 |
Standards | IEC 60332-1-2, DIN EN 60332-1-2, EN 60332-1-2, BS EN 60332-1-2 |
CPR | Eca |
Application | Instrumentation and Control Engineering, Industrial Electronics. |
EAN | 5056631512264 |
Flame Propagation Standard | Eca |