Modbus Cable SFX/3107A 2 Pairs 22AWG Overall Foil and Braided Screen 600V LSZH - Black 1000m
SFX/3107A-LSZH-BLK-1000
To become or find a stockist contact us
Modelled on the Belden 9841, Modbus cables as they are known are often the cable of choice for automation systems that require high speed data transmission for a range of RS-485 applications. The Securi-Flex® Modbus equivalents are high quality and provide low capacitance and enhanced noise protection.
RS485 is often compared to ethernet or RS232 as a communication standard, check out our guide on RS485 vs other communication standards for a comprehensive comparison of the various standards and which applications they are best suited to.
Results | |
AWG | 4 |
---|---|
Area (mm) | 4.8 |
Diameter (mm) | 7.8 |
SFX/3107A-LSZH-BLK-1000
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White, Orange & Blue, White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 9.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500759 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 75 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 8 |
Braid Coverage | >=65% |
Capacitance | 35pF/ft Nominal |
Impedance | 120Ω Nominal |
SFX/3107A-LSZH-BLK-500
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White, Orange & Blue, White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 9.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500773 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 27.5 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 8 |
Braid Coverage | >=65% |
Capacitance | 35pF/ft Nominal |
Impedance | 120Ω Nominal |
SFX/3107A-LSZH-BLK-200
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White, Orange & Blue, White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 9.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500766 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 15 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 8 |
Braid Coverage | >=65% |
Capacitance | 35pF/ft Nominal |
Impedance | 120Ω Nominal |
SFX/3107A-LSZH-BLK-100
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White, Orange & Blue, White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 9.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500742 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 7.5 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 8 |
Braid Coverage | >=65% |
Capacitance | 35pF/ft Nominal |
Impedance | 120Ω Nominal |
SFX/3107A-LSZH-BLK-1
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White, Orange & Blue, White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 9.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500735 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 0.075 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 8 |
Braid Coverage | >=65% |
Capacitance | 35pF/ft Nominal |
Impedance | 120Ω Nominal |
SFX/3106A-LSZH-BLK-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White,Orange |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% (Al side outside) |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 7.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500728 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 61 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 7 |
Braid Coverage | >=65% |
Cable Construction 2 | 1 Core |
Conductor 2 | Tinned Copper |
Stranded Diameter 2 (mm) | 0.36 |
Insulation 2 | LSZH |
Insulation 2 Colour(s) | Blue/White |
Insulation 2 Diameter (mm) | 1.80 ±0.10 |
Insulation 2 Thickness (mm) | 0.5 |
Al-PET Shield 2 | Outside Al-PET Shield |
SFX/3106A-LSZH-BLK-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White,Orange |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% (Al side outside) |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 1 |
Overall Diameter (mm) | 7.60 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500711 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 0.061 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 7 |
Braid Coverage | >=65% |
Cable Construction 2 | 1 Core |
Conductor 2 | Tinned Copper |
Stranded Diameter 2 (mm) | 0.36 |
Insulation 2 | LSZH |
Insulation 2 Colour(s) | Blue/White |
Insulation 2 Diameter (mm) | 1.80 ±0.10 |
Insulation 2 Thickness (mm) | 0.5 |
Al-PET Shield 2 | Outside Al-PET Shield |
SFX/3105A-LSZH-BLK-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White/Blue,Blue/White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.8 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500704 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 61 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 6 |
Braid Coverage | >=65% |
SFX/3105A-LSZH-BLK-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Insulation | FPE |
Insulation Thickness (mm) | 0.7 |
Insulation Colour | White/Blue,Blue/White |
Insulation Thickness 2 (mm) | 2.15 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.8 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For use in industrial communication systems (Modbus RS485). |
EAN | 5056631500698 |
Stranded Diameter (mm) | 0.36 |
AWG | 22 |
Drain Wire | Y |
Weight | 0.061 |
Flame Propagation Standard | Eca |
Drain wire conductor | Tinned Copper |
Braid | Tinned Copper |
Braid Construction | 0.11 ±0.008 x 16 x 6 |
Braid Coverage | >=65% |
SFX/OFB1-22-LSZH-PUR-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Bare Copper |
Conductor Diameter (mm) | 0.65 ±0.008 x 1(0.33mm²) |
Insulation | HDPE |
Insulation Thickness (mm) | 0.4 |
Insulation Colour | Red,Green |
Insulation Thickness 2 (mm) | 2.50 ±0.10 |
AI-PET Shield | >=115% |
Nylon Rip-Cord | 150D |
Jacket | LSZH |
Jacket Colour | Purple RAL 4005 |
Jacket Thickness (mm) | 0.9 |
Overall Diameter (mm) | 8.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Purple |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring in noisy environments. |
EAN | 5056631505051 |
Stranded Diameter (mm) | 0.64 |
AWG | 22 |
Drain Wire | N, Y |
Weight | 64 |
Flame Propagation Standard | Eca |
Drain wire conductor | N/A |
Braid | Tinned Copper |
Braid Construction | 0.15 ± 0.008 x 96 |
Braid Coverage | >=65% |
SFX/OFB1-22-LSZH-PUR-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Bare Copper |
Conductor Diameter (mm) | 0.65 ±0.008 x 1(0.33mm²) |
Insulation | HDPE |
Insulation Thickness (mm) | 0.4 |
Insulation Colour | Red,Green |
Insulation Thickness 2 (mm) | 2.50 ±0.10 |
AI-PET Shield | >=115% |
Nylon Rip-Cord | 150D |
Jacket | LSZH |
Jacket Colour | Purple RAL 4005 |
Jacket Thickness (mm) | 0.9 |
Overall Diameter (mm) | 8.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Purple |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring in noisy environments. |
EAN | 5056631505044 |
Stranded Diameter (mm) | 0.64 |
AWG | 22 |
Drain Wire | N, Y |
Weight | 0.064 |
Flame Propagation Standard | Eca |
Drain wire conductor | N/A |
Braid | Tinned Copper |
Braid Construction | 0.15 ± 0.008 x 96 |
Braid Coverage | >=65% |
SFX/USP1-18-MBUS-LSZH-PNK-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | Pink RAL 3015 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Pink |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Message bus (M-BUS). |
EAN | 5056631507093 |
Stranded Diameter (mm) | 0.81 |
AWG | 18 |
Drain Wire | N |
Weight | 90 |
Flame Propagation Standard | Eca |
SFX/USP1-18-MBUS-LSZH-PNK-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | Pink RAL 3015 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Pink |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Message bus (M-BUS). |
EAN | 5056631507086 |
Stranded Diameter (mm) | 0.81 |
AWG | 18 |
Drain Wire | N |
Weight | 0.09 |
Flame Propagation Standard | Eca |
SFX/USP1-18-EBUS-LSZH-WHT-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | White RAL 9003 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | White |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Energy bus (E-BUS). |
EAN | 5056631507024 |
Stranded Diameter (mm) | 0.81 |
AWG | 18 |
Drain Wire | N |
Weight | 90 |
Flame Propagation Standard | Eca |
SFX/USP1-18-EBUS-LSZH-WHT-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | White RAL 9003 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | White |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Energy bus (E-BUS). |
EAN | 5056631507017 |
Stranded Diameter (mm) | 0.81 |
AWG | 18 |
Drain Wire | N |
Weight | 0.09 |
Flame Propagation Standard | Eca |
SFX/USP1-18-EBUS-LSZH-BLU-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | Blue RAL 5015 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Blue |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Energy bus (E-BUS). |
EAN | 5056631507000 |
Stranded Diameter (mm) | 0.81 |
AWG | 18 |
Drain Wire | N |
Weight | 90 |
Flame Propagation Standard | Eca |
SFX/USP1-18-EBUS-LSZH-BLU-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | Blue RAL 5015 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Blue |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Energy bus (E-BUS). |
EAN | 5056631506997 |
Stranded Diameter (mm) | 0.81 |
AWG | 18 |
Drain Wire | N |
Weight | 0.09 |
Flame Propagation Standard | Eca |
SFXUSP118EBUSLSZHBLU100
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.30 ±0.008 mm × 16(0.82mm²) |
Insulation | LSZH |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.90 ±0.10 |
Jacket | LSZH |
Jacket Colour | Blue RAL 5015 |
Overall Diameter (mm) | 5.30 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Blue |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | For interconnecting Energy bus (E-BUS). |
EAN | 5056631510208 |
Stranded Diameter (mm) | 0.81 |
Feature 1 | Suitable for low voltage analog signals or low voltage digital control |
Feature 2 | Can be used for computer communication and line level audio |
Feature 3 | Low smoke zero halogen plastic is good for use inside public buildings and spaces as will not emit toxic gases if the cable catches fire |
Feature 4 | A multi purpose cable |
Feature 5 | Improved performance and protection against fire |
SFX/OFB1-22-LSZH-D-PUR-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Bare Copper |
Conductor Diameter (mm) | 0.65 ±0.008 x 1(0.33mm²) |
Insulation | HDPE |
Insulation Thickness (mm) | 0.4 |
Insulation Colour | Red,Green |
Insulation Thickness 2 (mm) | 2.50 ±0.10 |
AI-PET Shield | >=115% |
Nylon Rip-Cord | 150D |
Jacket | LSZH |
Jacket Colour | Purple RAL 4005 |
Jacket Thickness (mm) | 0.9 |
Overall Diameter (mm) | 8.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Purple |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Dca -s:2 -a:1 -d:2 |
Application | Audio, control, instrumentation and panel wiring in noisy environments. |
EAN | 5056631514893 |
SFX/OFB1-22-LSZH-D-PUR-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Bare Copper |
Conductor Diameter (mm) | 0.65 ±0.008 x 1(0.33mm²) |
Insulation | HDPE |
Insulation Thickness (mm) | 0.4 |
Insulation Colour | Red,Green |
Insulation Thickness 2 (mm) | 2.50 ±0.10 |
AI-PET Shield | >=115% |
Nylon Rip-Cord | 150D |
Jacket | LSZH |
Jacket Colour | Purple RAL 4005 |
Jacket Thickness (mm) | 0.9 |
Overall Diameter (mm) | 8.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Purple |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Dca -s:2 -a:1 -d:2 |
Application | Audio, control, instrumentation and panel wiring in noisy environments. |
EAN | 5056631514886 |