Belden Equivalent Cable OSP8 8pr 24AWG Overall Foil Screen Pairs 600V LSZH (9508) - Grey 1000m
SFX/OSP8-LSZH-GRY-1000
To become or find a stockist contact us
Our overall foil screen pair cable is designed for general use. The aluminium foil screening within the cable makes it a preferred choice for installations where protection from electrical interference is necessary.
Suitable for security, audio and data transmission, and instrumentation applications.
Results | |
AWG | 4 |
---|---|
Area (mm) | 4.8 |
Diameter (mm) | 7.8 |
SFX/OSP8-LSZH-GRY-1000
To become or find a stockist contact us
Conductor | Tinned Copper |
---|---|
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,White; 7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 8.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506294 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 100 |
SFX/OSP8-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 8 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,White; 7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 8.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506287 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.1 |
SFX/OSP6-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506270 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 55 |
SFX/OSP6-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506263 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.055 |
SFX/OSP6-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506232 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 73 |
SFX/OSP6-LSZH-GRY-500
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506256 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 36.5 |
SFX/OSP6-LSZH-GRY-200
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506249 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 14.6 |
SFX/OSP6-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506225 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 7.3 |
SFX/OSP6-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 6 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black;Yellow,Black;Brown,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 7.20 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506218 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.073 |
SFX/OSP4-SWA-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.32 |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 10.60 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631506201 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Inner Jacket | PE |
Inner Jacket Diameter (mm) | 6.80 ±0.20 |
Inner Jacket Thickness (mm) | 0.80 |
Inner Jacket Colour | Black RAL 9005 |
Armour | Galvanised Steel Wire |
Armour Construction (mm) | 0.90 x 26 |
Outer Jacket | PE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 1.00 ±0.03 |
Weight | 120 |
SFX/OSP4-SWA-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.32 |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket Colour | Black RAL 9005 |
Overall Diameter (mm) | 10.60 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631506195 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Inner Jacket | PE |
Inner Jacket Diameter (mm) | 6.80 ±0.20 |
Inner Jacket Thickness (mm) | 0.80 |
Inner Jacket Colour | Black RAL 9005 |
Armour | Galvanised Steel Wire |
Armour Construction (mm) | 0.90 x 26 |
Outer Jacket | PE |
Outer Jacket Colour | Black RAL 9005 |
Outer Jacket Thickness (mm) | 1.00 ±0.03 |
Weight | 0.12 |
SFX/OSP4-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506188 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 61 |
SFX/OSP4-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506171 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.061 |
SFX/OSP4-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506140 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 56 |
SFX/OSP4-LSZH-GRY-500
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506164 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 28.2 |
SFX/OSP4-LSZH-GRY-200
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506157 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 11.4 |
SFX/OSP4-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506133 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 5.6 |
SFX/OSP4-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 4 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black;Blue,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 6.80 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506126 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.056 |
SFX/OSP3-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 3 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.70 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506119 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 50 |
SFX/OSP3-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 3 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | PVC |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.70 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506102 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.05 |
SFX/OSP3-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 3 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.70 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506072 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 49 |
SFX/OSP3-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 3 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.70 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506065 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 4.9 |
SFX/OSP3-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 3 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black;Green,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.70 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506058 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.049 |
SFX/OSP2-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506034 |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 35 |
SFX/OSP2-LSZH-GRY-500
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506041 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 17.5 |
SFX/OSP2-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506027 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 3.5 |
SFX/OSP2-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 2 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | Red,Black;White,Black |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631506010 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.035 |
SFX/OSP19-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 19 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | 7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange; 6 pairs of Red with White,Green,Blue,Yellow,Brown,Orange; 5 pairs of Green with White,Blue,Yellow,Brown,Orange; White/Blue |
Insulation Thickness 2 (mm) | 1.15 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.85 |
Overall Diameter (mm) | 11.50 ±0.30 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631505976 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 270 |
SFX/OSP19-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 19 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | 7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange; 6 pairs of Red with White,Green,Blue,Yellow,Brown,Orange; 5 pairs of Green with White,Blue,Yellow,Brown,Orange; White/Blue |
Insulation Thickness 2 (mm) | 1.15 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.85 |
Overall Diameter (mm) | 11.50 ±0.30 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631505969 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.27 |
SFX/OSP15-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 15 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | 7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange; 6 pairs of Red with White,Green,Blue,Yellow,Brown,Orange; 2 pairs of Green with White,Blue |
Insulation Thickness 2 (mm) | 1.15 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.85 |
Overall Diameter (mm) | 10.50 ±0.30 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631505730 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 210 |
SFX/OSP15-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 15 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | 7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange; 6 pairs of Red with White,Green,Blue,Yellow,Brown,Orange; 2 pairs of Green with White,Blue |
Insulation Thickness 2 (mm) | 1.15 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.85 |
Overall Diameter (mm) | 10.50 ±0.30 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631505723 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.21 |
SFX/OSP10-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 10 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | 3 pairs of Red with White,Green,Blue;7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 9.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631505587 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 140 |
SFX/OSP10-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 10 Pairs |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 0.19 ±0.008 x 8(0.20mm²) |
AWG | 24 |
Insulation | LSZH |
Insulation Thickness (mm) | 0.28 |
Insulation Colour | 3 pairs of Red with White,Green,Blue;7 pairs of Black with Red,White,Green,Blue,Yellow,Brown,Orange |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.70 |
Overall Diameter (mm) | 9.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation, panel wiring and RS232 applications. |
EAN | 5056631505570 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.22 |
Drain wire conductor | Tinned Copper |
Weight | 0.14 |
SFX/OSP1-62-LSZH-GRY-500
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.28 |
AWG | 20 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.80 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505952 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.56 |
Drain wire conductor | Tinned Copper |
Weight | 19 |
SFX/OSP1-62-LSZH-GRY-200
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.28 |
AWG | 20 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.80 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505945 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.56 |
Drain wire conductor | Tinned Copper |
Weight | 7.6 |
SFX/OSP1-62-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.28 |
AWG | 20 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.80 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.00 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505921 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.56 |
Drain wire conductor | Tinned Copper |
Weight | 0.038 |
SFX/OSP1-61-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505914 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 27 |
SFX/OSP1-61-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505907 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 0.027 |
SFX/OSP1-61-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505877 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 27 |
SFX/OSP1-61-LSZH-GRY-500
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505891 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 13.5 |
SFX/OSP1-61-LSZH-GRY-200
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505884 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 5.4 |
SFX/OSP1-61-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505860 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 2.7 |
SFX/OSP1-61-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.43 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 1.55 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.6 |
Overall Diameter (mm) | 4.40 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505853 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 0.027 |
SFX/OSP1-60-SWA-UV-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket Colour | Grey RAL 7042 |
Overall Diameter (mm) | 9.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505846 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Inner Jacket | LSZH |
Inner Jacket Diameter (mm) | 5.50 ±0.20 |
Inner Jacket Thickness (mm) | 0.7 |
Inner Jacket Colour | Grey RAL 7042 |
Armour | Galvanised Steel Wire |
Armour Construction (mm) | 0.90 x 21 |
Outer Jacket | LSZH |
Outer Jacket Colour | Grey RAL 7042 |
Outer Jacket Thickness (mm) | 1.00 ±0.03 |
Weight | 80 |
SFX/OSP1-60-SWA-UV-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket Colour | Grey RAL 7042 |
Overall Diameter (mm) | 9.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505839 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Inner Jacket | LSZH |
Inner Jacket Diameter (mm) | 5.50 ±0.20 |
Inner Jacket Thickness (mm) | 0.7 |
Inner Jacket Colour | Grey RAL 7042 |
Armour | Galvanised Steel Wire |
Armour Construction (mm) | 0.90 x 21 |
Outer Jacket | LSZH |
Outer Jacket Colour | Grey RAL 7042 |
Outer Jacket Thickness (mm) | 1.00 ±0.03 |
Weight | 0.08 |
SFX/OSP1-60-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505808 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 40 |
SFX/OSP1-60-PE-BLK-500
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505822 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 22.5 |
SFX/OSP1-60-PE-BLK-200
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505815 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 9 |
SFX/OSP1-60-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505792 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 0.04 |
SFX/OSP1-60-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505761 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 45 |
SFX/OSP1-60-LSZH-GRY-500
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505785 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 20 |
SFX/OSP1-60-LSZH-GRY-200
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505778 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 9 |
SFX/OSP1-60-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505754 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 4.5 |
SFX/OSP1-60-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 16 x 0.30 |
AWG | 18 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.45 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 2.05 ±0.10 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.7 |
Overall Diameter (mm) | 5.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505747 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.81 |
Drain wire conductor | Tinned Copper |
Weight | 0.045 |
SFX/OSP1-22-LSZH-GRY-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.22 |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.55 |
Overall Diameter (mm) | 3.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505716 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 15 |
SFX/OSP1-22-LSZH-GRY-100
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.22 |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.55 |
Overall Diameter (mm) | 3.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505709 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 1.5 |
SFX/OSP1-22-LSZH-GRY-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 7 x 0.30 |
AWG | 22 |
Insulation | HDPE |
Insulation Thickness (mm) | 0.22 |
Insulation Colour | Black, Red |
Insulation Thickness 2 (mm) | 1.25 ±0.10 |
Drain Wire | Y |
AI-PET Shield | >=115% |
Jacket | LSZH |
Jacket Colour | Grey RAL 7042 |
Jacket Thickness (mm) | 0.55 |
Overall Diameter (mm) | 3.50 ±0.20 |
Overall Sheath | LSZH |
Overall Colour | Grey |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Eca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505693 |
Flame Propagation Standard | Eca |
Stranded Diameter (mm) | 0.36 |
Drain wire conductor | Tinned Copper |
Weight | 0.015 |
SFX/OSP1-19-PE-BLK-1000
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 19 x 0.3 |
AWG | 16, 18, 18 AWG |
Insulation | HDPE |
Insulation Thickness (mm) | 0.87 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 3.00 ±0.15 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.85 |
Overall Diameter (mm) | 8.00 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505686 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 1.30 |
Drain wire conductor | Tinned Copper |
Weight | 70 |
SFX/OSP1-19-PE-BLK-1
To become or find a stockist contact us
Cable Construction | 1 Pair |
---|---|
Conductor | Tinned Copper |
Conductor Diameter (mm) | 19 x 0.3 |
AWG | 16, 18, 18 AWG |
Insulation | HDPE |
Insulation Thickness (mm) | 0.87 |
Insulation Colour | Black, Clear |
Insulation Thickness 2 (mm) | 3.00 ±0.15 |
Drain Wire | N, Y |
AI-PET Shield | >=115% |
Jacket | PE |
Jacket Colour | Black RAL 9005 |
Jacket Thickness (mm) | 0.85 |
Overall Diameter (mm) | 8.00 ±0.20 |
Overall Sheath | PE |
Overall Colour | Black |
Rated Voltage (V) | 600V |
Standards | CE2014/30/EU, RoHS2 2011/65/EU, LVD 2014/35/EU |
CPR | Fca |
Application | Audio, control, instrumentation and panel wiring. |
EAN | 5056631505679 |
Flame Propagation Standard | Fca |
Stranded Diameter (mm) | 1.30 |
Drain wire conductor | Tinned Copper |
Weight | 0.07 |