Your are in:
Fire Resistant Cables | Fire Resistant Cabling >> Pyrofil Standard Fire Resistant Cable
Sub-Category: Pyrofil Standard Fire Resistant Cable
Pyrofil fire resistant cable is manufactured in Europe and is independently tested by LPCB and Basec, it is easy to prepare for termination and literally stays where you put it. Available in Red and White, 2 core - 12 core, 1.0mm - 2.5mm
Application
For use with fire alarm systems and emergency lighting for permament installation in buildings. Permitted operating temperature at conductor +90C.
Construction:
Conductor: Bare copper solid to IEC 60228, EN60228 and BS6360
Insulation: Double insulation, cross linked special compound according to BS7655, "E15"
Core Colours: 2 cores + earth blue, brown
3 cores + earth brown, black, grey
4 cores + earth blue, brown, black, grey
Inner covering: Glassfibre tape
Shielding: Al-laminated tape and tinned copper drain wire according to IEC60228, EN60228 and BS6360
Separator: Plastic tape
Sheath: Polyolefin compound according to BS7655, "ITS3"
Sheath Colour: Red, White (Other colours available upon request)
Electrical Properties: Nominal voltage 300/500V, Test voltage 2000V, 50Hz
General Properties:
Minimum Bend Radius: During and permanent installation 6 x D (D = Outer diameter)
Operating Temperature: Permanent installation: -15C to +90C, During Installation -5C to +50C
General Properties:
Zero Halogen non corrosive gases: IEC60754-1/-2, EN50267-2-1/-2-2, VDE0482-267-2-1/-2-2
Flame Retardant: IEC60332-1-2, EN60332-1-2, VDE0482-332-1-2
Fire Resistant: IEC 60332-3-22/-24 Cat. A/C, EN 50266-2-2/-4 Cat, A/C,
No flame propagation: VDE 0482-266-2-2/-4 Cat, A/C
Minimum Smoke Emission: IEC61034-1/-2, EN61034-1/-2 (EN 50268-1/-2),
Circuit Integrity: IEC 60331-11/-21 (180 minutes) VDE0472 part 814, BS 6387 CWZ,BS EN 50200 (PH120) and Annex E (30 minutes), BS8434-1 (30 minutes), VDE0482-200.
Application
For use with fire alarm systems and emergency lighting for permament installation in buildings. Permitted operating temperature at conductor +90C.
Construction:
Conductor: Bare copper solid to IEC 60228, EN60228 and BS6360
Insulation: Double insulation, cross linked special compound according to BS7655, "E15"
Core Colours: 2 cores + earth blue, brown
3 cores + earth brown, black, grey
4 cores + earth blue, brown, black, grey
Inner covering: Glassfibre tape
Shielding: Al-laminated tape and tinned copper drain wire according to IEC60228, EN60228 and BS6360
Separator: Plastic tape
Sheath: Polyolefin compound according to BS7655, "ITS3"
Sheath Colour: Red, White (Other colours available upon request)
Electrical Properties: Nominal voltage 300/500V, Test voltage 2000V, 50Hz
General Properties:
Minimum Bend Radius: During and permanent installation 6 x D (D = Outer diameter)
Operating Temperature: Permanent installation: -15C to +90C, During Installation -5C to +50C
General Properties:
Zero Halogen non corrosive gases: IEC60754-1/-2, EN50267-2-1/-2-2, VDE0482-267-2-1/-2-2
Flame Retardant: IEC60332-1-2, EN60332-1-2, VDE0482-332-1-2
Fire Resistant: IEC 60332-3-22/-24 Cat. A/C, EN 50266-2-2/-4 Cat, A/C,
No flame propagation: VDE 0482-266-2-2/-4 Cat, A/C
Minimum Smoke Emission: IEC61034-1/-2, EN61034-1/-2 (EN 50268-1/-2),
Circuit Integrity: IEC 60331-11/-21 (180 minutes) VDE0472 part 814, BS 6387 CWZ,BS EN 50200 (PH120) and Annex E (30 minutes), BS8434-1 (30 minutes), VDE0482-200.